MiMiC
v3 F.A.Q.'s
How will Models developed in MiMiC v2.x get migrated
to MiMiC v3?
How will Simulation Rentals be handled with MiMiC
v3?
Will the PROVOX and RS3 Drivers available on MiMiC
v2.x be available also on MiMiC v3?
Can I use my new MiMiC v3 license and still use
my MiMiC v2.8 license?
Will MiMiC v3 support DeltaV Simulate Speedup/Slowdown
capabilities?
Does MiMiC v3 support DeltaV SIS simulation?
Is a MiMiC v3 overview presentation available in
MS powerpoint format?
Does the Virtual IO Module need to be upgraded when
using MiMiC v3?
Does MYNAH have Bill of Materials examples for MiMiC
v3 Systems?
What languages are supported by MiMiC v3?
Does MiMiC v3 with the Virtual IO Module and DeltaV
Railbus Driver support ProfibusDP devices and card simulation?
What operating systems does MiMIC v3.0 support?
What is the largest capacity of process models
that MiMiC v3 can support?
What functionality is supported by MiMiC v2.8 and
not supported by MiMiC v3.0.0?
What is the official release of the new Virtual
IO Module for redundant Industrial Ethernet installations , VIM4201?
Does the user need to purchase and install the
MS SQL server license prior to installing MiMiC v3?
How many Soft Logic Solver 0of DeltaV SIS will one VIM simulate?
Is MiMiC v3 compatible with all DeltaV versions?
Is there a complete books online for MiMiC v3?
How does MiMiC v3 handle new types/models of FF
devices?
What are the Emerson Industry Center positions
with Mimic? Is it a standard tool?
In the past, there were conversion issues with using from simulations
developed for the VIM to the DeltaV Simulate OPC drivers. Has this been
addressed in MiMiC v3?
Any solution to using Virtual IO Modules with redundant
DeltaV controllers on vertical carriers?
If a customer is not using all of his SIO Tags,
do they have to pay full price for Software Support?
Will you still need to commission foundation fieldbus
devices in DeltaV with MiMiC?
If you have an existing MiMiC system that is current
on MiMiC Software Support will MYNAH upgrade the user to MiMiC v3 at no
extra cost?
Does MiMiC v3 have a Simulated IO driver for DeltaV
for Provox and RS3 I/O?
How is OPC communication configured, with DeltaV
Simulate and other off-line automation system simulation packages? Master
or slave, do you need OPC mirror?
Are SIO tags used to define inputs and outputs
of the simulation model and are different definition files used to connect
SIO tags to external data structure?
What DeltaV IO Modules are supported with the DeltaV
Railbus SIO Driver in MiMiC v3?
Is there documentation about the Simulation Function
Blocks?
Is there are limitation of the number of columns
that can be simulated using the MiMiC Distillation Modeling Application
Package?
If MiMiC if used for Operator Training with DeltaV
Simulate and the actual system has Fieldbus, should the user run the DeltaV
Simulate Convert utility before exporting the FHX file for the MiMiC v3
Database Generator?
How are SIO Tags counted in MiMiC v3?
In MiMiC v2.8, OPC parameters can be simulated
using the /OPC designation in the Tag name. Can the user simulate OPC
parameters in MiMiC v3 and do they consume SIO tags?
Will the user who is using MiMiC v3.0.0 be able
to upgrade to future releases of MiMiC v3?
Should we continue to use a complete DeltaV database
export to generate the MiMiC Simulation database or will the utility accept
partial exports?
Is there a utility for bulk loading MiMiC Simulation
as opposed to generating from the DeltaV fhx file?
How many SIO Tags are included in the base version
of MiMIC v3?
Is it possible to have redundant Virtual IO Modules
for simulation for redundant controllers?
Can the user have a mix of real IO modules and
simulated IO with MiMiC and the Virtual IO Module on the same controller?
How will MiMiC v2.x licenses be converted to MiMiC
v3 licenses?
Is the same Virtual IO Module hardware used for
MiMiC simulation also used for the DeltaV Virtual IO Module Network Gateway?
Will MiMiC v2.x Calc Expressions be migrated to
MiMiC v3?
Does the MiMiC v3 Delta Database Generator work
with the databases that use encrypted class-based modules?
AMS inside has been removed from DeltaV 9 and
AMS 9 will be installed instead. Will it be possible to use AMS HART with
MIMIC in the next release? In the current release AMS generate error when
MIMIC is connected. The same question for FF devices.
Some field devices uses 0 - 4 mA as a range to
indicate fault and maintenance conditions. Does MiMiC v3 support negative
EU ranges?
Is it possible to sort and search tags in MiMiC
v3. For a small system it is not necessary but for big system it is very
difficult to find specific tag?
Does MIMiC support simulation for DeltaV Zone
1 and Zone 2 Remote I/O?
Is it possible to generate a device fault for
FF, ProfiBus, Asi, DeviceNet, so that it is possible to test what happened
in the application when one device fails? Item ditto for special protocols
like Modbus to disable one dataset and to check how the application manage
with it.
Can MiMiC v3 simulate serial and digital bus IO
data at the bit level?
Can you monitor output and input values at the
same window or in a split window?
Can an entire simulation system be launched from
a one command?
Is there a runtime version that is sold separate
from the development version?
Are there any modifiers that can be configured
within the tieback blocks?
Is the MiMIC v3 calculation block expression syntax
limited to Mimic v2.x syntax, or are there be additional functions and
data types?
Are logic function blocks such as AND, OR, etc.
available for the simulation diagrams? Are there simpler ways to do flow
paths in MiMiC v3 than writing a Calc?
Is commenting of FB diagrams & Calc expressions
available in MiMiC v3?
Does the user have to sync off-line and on-line
databases in MiMiC v3?
Is the user able to modify the run-time models
during operation?
Is there a user interface to view the SIO Tags
only?
Does MiMiC v3 have online help and context-sensitive
help?
Does MiMiC v3 require server type machines? Does
it run also on workstations?
Any thought to having a live link between DeltaV
and MiMic so that if parameters are changed in DeltaV they will automatically
be updated in MiMiC?
When is support for DeltaV SIS planned?
Are there any plans to emulate more of the AMS
functions of Foundation Fieldbus devices? Have scenarios where operators
need to use AMS to standardize probes from DeltaV Operator using AMS menu's.
It would be nice to emulate this in simulation.
When the user purchases a MiMiC system, what do
they receive from MYNAH?
When the user rents a MiMiC system, what do they
receive from MYNAH?
Is it possible for multiple users to be working
on MiMiC v3 from separate remote desktop stations?
What is the execution rate of a MiMiC v3 simulation
model to read a channel, tieback, calc, write value back to I/O system?
What DeltaV IO cards does MiMiC v3 support with
the Delta Railbus SIO Driver and the Virtual IO Module?
Is it possible to use DeltaV DST name as the name
for the SIO tag?
Are there plans to improve the performance of
the DeltaV FHX Utility?
Is it possible to get FF devices to show up commissioned
without having to individually commission each device?
Is it possible to add a utility to decommission
all FF devices in the end FAT?
Does MiMiC v3 support speedup / slowdown capabilities
of the simulation engine and models?
Is there limitation in the number of characters
in the fully-qualified OPC data path?
Is there any way to automate the generation of
FF definitions for new devices?
Is the engineering unit conversion of the streams
automatic?
How is filtering and sorting handled in the MView
Data View?
Is the trend data in MiMiC Data Monitor historical?
Or once the value scrolls off the trend is it lost?
In MiMiC Component Studio is there a graphical
control that supports scripting or a macro? For example: one button that
will initialize all the levels of the raw material tanks?
Is it possible to filter on whether or not the
channels are enabled?
In the Data Monitor Trend view is the time recorded
for the trend value synchronized with the MIMIC simulation rate? For example:
if the simulation rate is x2 the trend recording is also x2?
Does the 10X speedup/slowdown work DeltaV Simulate?
How will it work with DeltaV OPC updates of only 500 ms?
Can I use the new Virtual IO Module for Redundant
applications, VIM-4201, with the DeltaV Railbus SIO Driver and MiMiC?
Is MiMiC Software Support included with the MiMiC
Base License Purchase?
How can I find out when my MiMiC Software Support
expires?
How can I know my MiMiC Site ID?
How can I know what software licenses I own?
When do I have to quit using my MiMiC v2.8 license
once I receive my MiMiC v3 media pack?
Are there any new enhancements planned for MiMiC
v2.x?
How long will MYNAH continue to support MiMiC
v2.x?
How
will Models developed in MiMiC v2.x get migrated to MiMiC v3?
We will be releasing a migration utility in the second release of MiMiC
v3 (late spring 2008) that will take the MiMiC v2.x files and generate
a MiMiC v3 database. The migration process will be complete, but it will
not change the modeling structure of the v2.x simulation. Each Tieback,
Tag or Calc in v2.x will be migrated to a separate model in v3. Operator
training scenarios will need to be rebuilt in the MiMiC v3 Operator Training
Manager.
back to top
How
will Simulation Rentals be handled with MiMiC v3?
MYNAH will be offering software only license rentals through the Emerson
LBPs and Sales and Engineering offices. When the order for the rental
is placed MYNAH will send the renting office download instructions and
a site validation file. Rentals are available on a monthly basis with
a minimum of one month rental.
back to top
Will
the PROVOX and RS3 Drivers available on MiMiC v2.x be available also on
MiMiC v3?
Not at this time. Because of technical limitations with the existing driver
technology, we cannot move these drivers to MiMiC v3. We are exploring
options with Austin Technology for different IO simulation methods for
both RS3 and PROVOX. Customers that have a need for PROVOX or RS3 IO simulation
should use MiMiC v2.8.49.
back to top
Can
I use my new MiMiC v3 license and still use my MiMiC v2.8 license?
Yes, as long as your MiMiC v3 license is current on MiMiC Software Support.
back to top
Will
MiMiC v3 support DeltaV Simulate Speedup/Slowdown capabilities?
Not in the initial release but this is a planned enhancement for 2008.
We will support a speedup/slowdown factor of 10x. Because of limitations
in the module execution speed in DeltaV (100 msec) and the DeltaV OPC
Server update rate of 500ms, this will require review and possible modifications
of the DeltaV database. We will document the changes needed to the DeltaV
database in a white paper with the release of this driver.
back to top
Does
MiMiC v3 support DeltaV SIS simulation?
Yes, MiMiC v3 has a driver for DeltaV Simulate SIS. Because DeltaV Simulate
SIS will not be available until the DeltaV v10.3 release we will release
the MiMiC driver later this summer.
back to top
Is
a MiMiC v3 overview presentation available in MS powerpoint format?
Yes, an overview presentation and the presentation from the Emerson introduction
training is available on the partner portal sites.
back to top
Does
the Virtual IO Module need to be upgraded when using MiMiC v3?
It is always a good idea to use the latest Virtual IO Module firmware.
The current Virtual IO Module firmware for MiMiC v2.8.49 and MiMiC v3.0.0
is v2.2.6. The firmware is included in the MiMiC v3.0.0 software distribution
and can be flashed in the MiMiC v3 Explorer under the DeltaV IO Tab.
back to top
Does
MYNAH have Bill of Materials examples for MiMiC v3 Systems?
Yes, example Bill of Materials are included in section 4 of the Emerson
Price Book.
back to top
What
languages are supported by MiMiC v3?
Currently English only. We will be looking at multiple language support
in 2009.
back to top
Does
MiMiC v3 with the Virtual IO Module and DeltaV Railbus Driver support
ProfibusDP devices and card simulation?
Yes, MiMiC v3 with Virtual IO Module v2.2.6 supports all DeltaV IO cards
including ProfibusDP Series 2 modules.
back to top
What
operating systems does MiMIC v3.0 support?
MiMiC v3.0 currently supports MS Windows XP SP2 or higher and Server 2003.
We are reviewing the release of service packs and adoption of MS Vista
to determine when we should support it.
back to top
What
is the largest capacity of process models that MiMiC v3 can support?
There is no limit on the number of process models in MiMiC v3. The only
limit is the number of run-time Simulated IO Tags (SIO) that are licensed
to the user. We offer SIO tag licenses of 1000 to 30,000 tags in 1000
tag increments.
back to top
What
functionality is supported by MiMiC v2.8 and not supported by MiMiC v3.0.0?
The following MiMiC v2.8 functionality is not currently supported in MiMiC
v3.0.0. Customers who have the functionality can continue to use their
MiMiC v2.8 release for simulations that require it as long as they are
current on MiMiC Software Support;
MiMiC v2.8 functionality not currently supported in MiMiC v3:
• PROVOX Simulation Driver Pack
• RS3 Simulation Driver Pack
• Allen-Bradley Driver Pack
• TI Driver Pack
• GE Driver Pack
• Modicon Driver Pack (Unity is support in v3.0.0)
• Distillation Application Package
• Boiler Application Package
• Simulation Objects
back to top
What
is the official release of the new Virtual IO Module for redundant Industrial
Ethernet installations , VIM4201?
The product was released in March 2008. It uses the same firmware as the
MIM-4207. This module should only be used for redundant Modbus TCP/IP
and Ethernet/IP installations only. Simplex installations and use with
MiMiC should continue to use the MIM-4207.
back to top
Does
the user need to purchase and install the MS SQL server license prior
to installing MiMiC v3?
No, the MiMiC v3 Installer checks for the presence of MS SQL Server before
installation. If it does not find it, it installs MS SQL Server Express
from the MiMiC software distribution. No additional license is required
for the use of MS SQL Server Express.
back to top
How
many Soft Logic Solver 0of DeltaV SIS will one VIM simulate?
None! The Soft Logic Solver is simulated with DeltaV Simulate SIS in DeltaV
v10.3. MiMiC v3 reads and writes the soft IO channels of the Soft Logic
Solver using the DeltaV SIS OPC SIO Driver.
back to top
Is
MiMiC v3 compatible with all DeltaV versions?
We support use of MiMiC v3 with DeltaV v6.3 through v9.3. We are starting
testing on v10 and will support it prior to the release.
back to top
Is
there a complete books online for MiMiC v3?
Yes, a complete HTML help system is built into MiMiC v3. You can also
review the MiMiC v3 Help System online at http://www.mynah.com/webhelp_output/Default.htm.
back to top
How
does MiMiC v3 handle new types/models of FF devices?
The current process is the same as with MiMiC v2.8. A list of supported
device is posted on the MYNAH Forum and is included in the MiMiC v3 software
distribution under the Fieldbus folder. If a device you are using is not
supported, send the FHX file to the MYNAH support staff and they will
send back the device definition.
back to top
What
are the Emerson Industry Center positions with Mimic? Is it a standard
tool?
Probably need to ask the individual engineering center but most Emerson
engineering centers globally have at least one MiMiC license. Some of
them like the RCIC, HEIC, EEEC, Singapore, and Rijwijk have extensive
investments in MiMiC for DeltaV Software Acceptance Testing. In addition,
the DeltaV Development group in Austin uses MiMiC for integrated and load
testing of DeltaV releases.
back to top
In
the past, there were conversion issues with using from simulations developed
for the VIM to the DeltaV Simulate OPC drivers. Has this been addressed
in MiMiC v3?
Yes, in MiMiC v3 the simulations are completely portable between different
simulation drivers. In MiMiC v3 the models read and write data to simulated
IO tags (SIO). The SIO tag directs the read or write to the appropriate
IO assignment or fully-qualified data path using the SIO bridge services.
To switch a process model between simulation for direct DeltaV IO and
DeltaV Simulate parameters is as simple as stopping the simulation node,
and re-starting it with a different SIO definition.
back to top
Any
solution to using Virtual IO Modules with redundant DeltaV controllers
on vertical carriers?
Unfortunately no. The vertical carriers are made such that only one 4-wide
controller carrier can be installed and if you have redundant controllers
you do not have a controller slot to install the VIM. Please see the topic
posted on the MYNAH Forum at http://www.mynah.com/forum/forum_posts.asp?TID=161
for more details.
back to top
If
a customer is not using all of his SIO Tags, do they have to pay full
price for Software Support?
There is no way for us to monitor the amount of SIO Tags being used on
a system. MiMiC Software Support is based upon the run-time capacity of
SIO Tags licensed to the end user. If the user wants to downsize their
system we can allow that but if they change their mind later and want
the larger size they will have to pay for the upgrade.
back to top
Will
you still need to commission foundation fieldbus devices in DeltaV with
MiMiC?
Yes, we have no ability to change the DeltaV Foundation Fieldbus commissioning
procedure.
back to top
If
you have an existing MiMiC system that is current on MiMiC Software Support
will MYNAH upgrade the user to MiMiC v3 at no extra cost?
Yes!
back to top
Does
MiMiC v3 have a Simulated IO driver for DeltaV for Provox and RS3 I/O?
Not at this time due to technical limitations in the interfaces. We are
working with Emerson Technology to look at options for simulation for
DeltaV for PROVOX and RS3 IO.
back to top
How
is OPC communication configured, with DeltaV Simulate and other off-line
automation system simulation packages? Master or slave, do you need OPC
mirror?
The MiMiC v3 OPC SIO Bridge is an OPC Client that talks to the DeltaV
Simulate OPC Server or other off-line automation system simulation systems
that have an OPC Server. No OPC Mirror required.
back to top
Are
SIO tags used to define inputs and outputs of the simulation model and
are different definition files used to connect SIO tags to external data
structure?
Yes, the simulation models reference and read/write from the SIO Tags.
The SIO system converts the signals to the IO definition or the fully-qualified
path of the data.
back to top
What
DeltaV IO Modules are supported with the DeltaV Railbus SIO Driver in
MiMiC v3?
All current DeltaV IO Modules including Foundation Fieldbus, ProfibusDP,
DeviceNet, Asibus, and Serial IO.
back to top
Is
there documentation about the Simulation Function Blocks?
Yes, the MiMiC On-line Help in the MiMiC Software Media has definition
of all MiMiC Modeling Blocks. You can also review the MiMiC v3 Help System
online at http://www.mynah.com/webhelp_output/Default.htm.
back to top
Is
there are limitation of the number of columns that can be simulated using
the MiMiC Distillation Modeling Application Package?
No.
back to top
If
MiMiC if used for Operator Training with DeltaV Simulate and the actual
system has Fieldbus, should the user run the DeltaV Simulate Convert utility
before exporting the FHX file for the MiMiC v3 Database Generator?
No, with MiMiC v3 we recommend running the utility on the production database.
The DeltaV Database Generator Utility will generate an SIO definition
for the VIM and one with the fully-qualified OPC paths. Once you have
done that you can copy the DeltaV database and prepare it to run in DeltaV
Simulate, including running the Simulate Convert Utility.
back to top
How
are SIO Tags counted in MiMiC v3?
An SIO Tag is a data value link between the simulation models in the MiMiC
Nodes and the off-line automation system. SIO Tags are consumed when Nodes
are started and they are released when Nodes are stopped. Many digital
bus IO functions may be handled in the DeltaV VIM Bridge and not count
as SIO Tags. When a Node is generated from DeltaV using the DeltaV Database
Generator the amount of SIO Tags are viewable in the MiMiC Explorer. In
general, DST count is a good indication of SIO Tag requirements.
back to top
In
MiMiC v2.8, OPC parameters can be simulated using the /OPC designation
in the Tag name. Can the user simulate OPC parameters in MiMiC v3 and
do they consume SIO tags?
In MiMiC v3, the SIO Tag has a fully-qualified OPC path for each Tag.
Each OPC read or write consumes a SIO Tag. Adding new values of interest
is very easy. The user can name the tag and then browse to the OPC data
parameter of interest.
back to top
Will
the user who is using MiMiC v3.0.0 be able to upgrade to future releases
of MiMiC v3?
Yes, as long as the system is current on MiMiC Software Support all revision
upgrades are provided at no additional charge.
back to top
Should
we continue to use a complete DeltaV database export to generate the MiMiC
Simulation database or will the utility accept partial exports?
For the initial MiMiC database generation, the user should do a total
DeltaV database export. After that initial database generation, the user
can do partial exports of the components in DeltaV that changed, convert
them to XML using the MiMiC Database Generator Utility and then import
the changes into MiMiC.
back to top
Is
there a utility for bulk loading MiMiC Simulation as opposed to generating
from the DeltaV fhx file?
In MiMiC v3.0.0 you can bulk load XML files into MiMiC to build any part
of the simulation definition. We are considering the development of off-line
simulation development utilities in the future that use the XML standard
(like Excel 2007).
back to top
How
many SIO Tags are included in the base version of MiMIC v3?
The smallest license for MiMiC v3 is 1000 SIO Tags.
back to top
Is
it possible to have redundant Virtual IO Modules for simulation for redundant
controllers?
No, but with one Virtual IO Module and MiMiC you can simulate all 64 IO
cards including redundant DeltaV IO cards.
back to top
Can
the user have a mix of real IO modules and simulated IO with MiMiC and
the Virtual IO Module on the same controller?
Yes, as long as the real IO and simulated IO are not addressed to the
same DeltaV IO positions.
back to top
How
will MiMiC v2.x licenses be converted to MiMiC v3 licenses?
Please see the topic on the MYNAH Forum at http://www.mynah.com/forum/forum_posts.asp?TID=252.
back to top
Is
the same Virtual IO Module hardware used for MiMiC simulation also used
for the DeltaV Virtual IO Module Network Gateway?
Yes, the only difference is the software license and the firmware flash.
back to top
Will
MiMiC v2.x Calc Expressions be migrated to MiMiC v3?
Yes, the v2.x to v3 simulation migration utility will migrate each v2.x
Calc object into a Model in MiMiC v3 that has a CALC Modeling Block duplicating
the expression that runs in the v2.x object.
back to top
Does
the MiMiC v3 Delta Database Generator work with the databases that use
encrypted class-based modules?
Yes, please see the instructions in the MiMiC v3 Online Help at http://www.mynah.com/webhelp_output/Default.htm.
back to top
AMS
inside has been removed from DeltaV 9 and AMS 9 will be installed instead.
Will it be possible to use AMS HART with MIMIC in the next release? In
the current release AMS generate error when MIMIC is connected. The same
question for FF devices.
We are waiting for our v9.3 release and then we will be testing
both functions.
back to top
Some
field devices uses 0 - 4 mA as a range to indicate fault and maintenance
conditions. Does MiMiC v3 support negative EU ranges?
Yes, you can specify negative EU in MiMiC v3.
back to top
Is
it possible to sort and search tags in MiMiC v3. For a small system it
is not necessary but for big system it is very difficult to find specific
tag?
Yes, advanced search and sorting capabilities are built into MiMiC Explorer
and MView application in MiMiC v3.
back to top
Does
MIMiC support simulation for DeltaV Zone 1 and Zone 2 Remote I/O?
Zone 2 IO cards and signals can be simulated using the VIM. There is no
simulation solution for Zone 1 IO. Because Zone 1 and 2 IO is classic
style IO, we are recommending that users re-assign the modules to the
workstation and use the DeltaV Simulate OPC Client Driver to test their
DeltaV application software. This is not an ideal solution, but discussions
with marketing to develop a better simulation interface to Zone 1 or Zone
2 IO were stopped.
back to top
Is
it possible to generate a device fault for FF, ProfiBus, Asi, DeviceNet,
so that it is possible to test what happened in the application when one
device fails? Item ditto for special protocols like Modbus to disable
one dataset and to check how the application manage with it.
We are looking at a method to allow the user to set device fault
alarms for digital bus devices.
back to top
Can
MiMiC v3 simulate serial and digital bus IO data at the bit level?
Yes, please see the MYNAH Forum topic on serial and bit level simulation
at
back to top
Can
you monitor output and input values at the same window or in a split window?
Yes, in MiMiC v3, you can define a MView that shows IO values from input
and outputs SIO tags or modeling blocks in a split window.
back to top
Can
an entire simulation system be launched from a one command?
Yes, in the MiMiC Explorer, select Edit, Preferences, Use Auto-Start Node
Settings. This setting saves the last state of the simulation and allows
the user to start all nodes at their last state by starting the MiMiC
Explorer.
back to top
Is
there a runtime version that is sold separate from the development version?
Not at this time. Any MiMiC system can be used to develop any size simulation
while the run-time is limited by the SIO tag count. The smallest MiMiC
system (1000 SIO Tag) gives the ability for unlimited development and
1000 SIO Tags in runtime.
back to top
Are
there any modifiers that can be configured within the tieback blocks?
Yes, the Loop Tieback (LTB) and Discrete Tieback (DTB) have many parameters
that can be modified to affect the performance of the tieback. Please
refer to the Modeling Block Reference in the online help for a complete
list of parameters.
back to top
Is
the MiMIC v3 calculation block expression syntax limited to Mimic v2.x
syntax, or are there be additional functions and data types?
There are additions to the calc block expressions not available
in MiMiC v2.x. In addition, you can add comments into the Calc Modeling
Blocks expression in MiMiC v3. MiMiC v3 also has global registers that
allow transfer of data between models or simulation Nodes.
back to top
Are
logic function blocks such as AND, OR, etc. available for the simulation
diagrams? Are there simpler ways to do flow paths in MiMiC v3 than writing
a Calc?
Yes. There are additions to the calc block expressions and MiMiC
function blocks that are not available in MiMiC v2. These will include
the logical blocks like AND and OR. In addition, there is a new conditional
Block (CND) that is designed to quickly define a flow path.
back to top
Is
commenting of FB diagrams & Calc expressions available in MiMiC v3?
Yes, comments can be added to FB diagrams and Calc expressions.
back to top
Does
the user have to sync off-line and on-line databases in MiMiC v3?
Changes made on-line are added to the off-line database by saving the
model either during viewing and changing on-line or when exiting Simulation
Studio. Moving between the off-line model construction and on-line model
execution viewing are a fast one-button operation.
back to top
Is
the user able to modify the run-time models during operation?
Yes, run-time modifications can be made in Simulation Studio and with
partial updates back into the MiMiC Simulation Engine and database.
back to top
Is
there a user interface to view the SIO Tags only?
An MView display can be defined to view the SIO Tags. The user can customize
this view like any of the data views.
back to top
Does
MiMiC v3 have online help and context-sensitive help?
Yes, there is an HTML help system for MiMiC v3 that is part of the MiMiC
distribution and can also be viewed on the MYNAH web site. Text tools
and what’s this are also integrated into all modeling blocks and
applications.
back to top
Does
MiMiC v3 require server type machines? Does it run also on workstations?
MiMiC v3 will run on Win XP SP2 and Server 2003. We will also support
Vista in a future release. Server2003 or server machines are not required
but in order to have multiple users working with the same MiMiC Server
it must be installed on the Server 2003 operating system.
back to top
Any
thought to having a live link between DeltaV and MiMic so that if parameters
are changed in DeltaV they will automatically be updated in MiMiC?
It is a great idea and something we have talked to Emerson about for future
DeltaV product enhancements. We are working on the first step of this
capability with the Web Services interface available in DeltaV v10.3.
back to top
When
is support for DeltaV SIS planned?
Support for DeltaV SIS is dependent upon DeltaV SiS Simulate available
in v10.3. We will release our SIO Driver for MiMiC v3 before Emerson’s
release of this product.
back to top Are
there any plans to emulate more of the AMS functions of Foundation Fieldbus
devices? Have scenarios where operators need to use AMS to standardize
probes from DeltaV Operator using AMS menu's. It would be nice to emulate
this in simulation.
MiMiC v3 does not support device specific function simulation of FF and
focused on the open function blocks. We have talked about methods where
the user could trigger signals that appear in AMS but we do not have any
current development in place.
back to top
When
the user purchases a MiMiC system, what do they receive from MYNAH?
MiMiC purchases from MYNAH include simulation software licenses and simulation
hardware, like the DeltaV Virtual IO Module. All commercial off-the-shelf
hardware like PCs can be provided by the end user of local office. Installing
and setting up MiMiC on the PC is simple and fast.
back to top
When
the user rents a MiMiC system, what do they receive from MYNAH?
MiMiC rental from MYNAH include a time-based simulation software license
only. MiMiC software licenses can be rented in one month periods. All
simulation hardware, like the DeltaV Virtual IO Module, PC and network
hardware should be provided by the local office. Installing and setting
up MiMiC on the PC is simple and fast.
back to top
Is
it possible for multiple users to be working on MiMiC v3 from separate
remote desktop stations?
Yes, MiMiC v3 is fully compatible with Win XP Remote Desktop and Server
2003 Remote Terminal Services. In order to support up to 10 Remote Terminal
Sessions from one machine MiMiC will need to be loaded on Server 2003
and the customer will need to purchase the MiMiC Server license.
back to top
What
is the execution rate of a MiMiC v3 simulation model to read a channel,
tieback, calc, write value back to I/O system?
V3.0.0 release of MiMiC v3 supports total model execution time of 1 sec.
In future releases it will support 250 msec total model execution time.
Model execution time can be seen in MiMiC Diagnostics.
back to top
What
DeltaV IO cards does MiMiC v3 support with the Delta Railbus SIO Driver
and the Virtual IO Module?
All DeltaV IO cards available in DeltaV v9.3.
back to top
Is
it possible to use DeltaV DST name as the name for the SIO tag?
Yes, the SIO tag can be named to match the DeltaV DST or any
other name. The DeltaV Database Generator uses the DST name for the SIO
tag name when generating the SIO tags.
back to top
Are
there plans to improve the performance of the DeltaV FHX Utility?
The DeltaV Database Generator in MiMiC v3 has been optimized
further. Moving to the SQL Server Express database has helped performance
a lot. We are working on a different approach to simulation generation
that will use the Web Services capabilities in DeltaV v10. We are optimistic
that interface will also improve simulation generation performance significantly.
back to top
Is
it possible to get FF devices to show up commissioned without having to
individually commission each device?
We can’t do this without major changes in the way DeltaV handles
FF devices. There are projects being considered by Emerson for optimizing
FF commissioning.
back to top
Is
it possible to add a utility to decommission all FF devices in the end
FAT?
We could do this in MiMiC but DeltaV would still require you to decommission
all devices via DeltaV Explorer.
back to top
Does
MiMiC v3 support speedup / slowdown capabilities of the simulation engine
and models?
Speedup / slowdown 10x is designed into the simulation engine, and will
be released in 2008.
back to top
Is
there limitation in the number of characters in the fully-qualified OPC
data path?
The field for the fully qualified OPC data path in the SIO tag
is 256 characters.
back to top
Is
there any way to automate the generation of FF definitions for new devices?
The current version of the DeltaV Database Generator does not
support automatic generation of new devices. We are planning on an enhancement
of this utility that will create new Foundation Fieldbus devices automatically.
back to top
Is
the engineering unit conversion of the streams automatic?
Yes, the engineering unit conversions automatic in MiMiC v3. Our simulation
consultants claim this feature will save 10% of the time and cost associated
with developing and maintaining process simulations.
back to top How
is filtering and sorting handled in the MView Data View?
The user can select the tags or data that he would like to display in
the edit view window. The data displayed can be filtered by Model Name,
Node Name, and Model block type. The parameters displayed can be also
selected in the window. The user can sort be selecting the column (similar
to Excel).
back to top
Is
the trend data in MiMiC Data Monitor historical? Or once the value scrolls
off the trend is it lost?
The trend data from the MiMiC Data Monitor can be saved to a SQL table
on the MiMiC server. The historical data collection is only active as
the Data Monitor View window is open and active.
back to top
In
MiMiC Component Studio is there a graphical control that supports scripting
or a macro? For example: one button that will initialize all the levels
of the raw material tanks?
This can be done be making a script in a Calc block within a model or
as a step of a training scenario. Adding a button to enable either scripts
is available in the Component Studio editor.
back to top
Is
it possible to filter on whether or not the channels are enabled?
Not exactly. You can browse for specific SIO tags but if the channels
are enabled in DeltaV is not visible to MiMiC. SIO tags by definition
usually refer to enabled channels only.
back to top
In
the Data Monitor Trend view is the time recorded for the trend value synchronized
with the MIMIC simulation rate? For example: if the simulation rate is
x2 the trend recording is also x2?
The Data Monitor Trend View time record is captured based upon the sample
rate configured in the Trend View dialog. Samples can be captured as fast
as 200 msec.
back to top
Does
the 10X speedup/slowdown work DeltaV Simulate? How will it work with DeltaV
OPC updates of only 500 ms?
Yes, the speedup / slowdown controls planned for the third release of
MiMiC v3 will only work with the DeltaV Simulate OPC driver. The DeltaV
SimulatePro controls changes the execution time of the module to make
it as fast as 100 msec. In MiMiC we will need to update our model execution
time accordingly. We planned for this in v3 and can support it. DeltaV
users will need to review their module executions to make sure that the
fastest module does not run faster than 1 sec. We will be publishing an
application paper on how to engineer the DeltaV database when we release
this capability.
back to top
Can
I use the new Virtual IO Module for Redundant applications, VIM-4201,
with the DeltaV Railbus SIO Driver and MiMiC?
No, we have not tested this product with MiMiC. We recommend the MIM-4207
Virtual IO Module for use with MiMiC at this time.
back to top
Is
MiMiC Software Support included with the MiMiC Base License Purchase?
Yes, one year of MiMiC Software Support from date of initial shipment
is included in the MiMiC Base Software License purchase.
back to top
How
can I find out when my MiMiC Software Support expires?
The expiration date for the MiMiC Software Support renewal is shown on
the bottom right hand border of the MiMiC Explorer.
back to top
How
can I know my MiMiC Site ID?
The MiMiC Site ID is shown on the bottom left hand border of the MiMiC
Explorer.
back to top
How
can I know what software licenses I own?
The MiMiC Software License certificate that ships with the initial MiMiC
system purchase shows the software options licensed. In the MiMiC Explorer
the user can also view the licenses by selecting Tools, Check Licensing.
back to top
When
do I have to quit using my MiMiC v2.8 license once I receive my MiMiC
v3 media pack?
The user can continue to use MiMiC v2.8 and the new MiMiC v3 license as
long as they are current on MiMiC Software Support.
back to top
Are
there any new enhancements planned for MiMiC v2.x?
No, the final release of MiMiC v2.x is v2.8.49. There are no planned releases
of MiMiC v2.x after this release. MiMiC v2.x is now at a MATURE status.
back to top
How
long will MYNAH continue to support MiMiC v2.x?
MiMiC v2.x went to MATURE status in March 2008. We will continue to support
MiMiC v2.8.49 until March 2018 for those customers that are current on
MiMiC Software Support.
back to top
|